3-1
CHAPTER 3
MAINTENANCE
SECTION I
MAINTENANCE AND TROUBLESHOOTING
WARNING
Prior to conducting routine or periodic
maintenance on the ATPIAL, ensure the Mode
Selector is turned to the O (OFF) position.
3.1 TROUBLESHOOTING
The procedures below will help correct some of the basic
problems that may arise with the ATPIAL. If the equipment
malfunction is not listed, or the actions listed do not correct
the fault, refer to section 3.4 for additional guidance.
Table 3-1. Troubleshooting Procedures.
Malfunction
Probable Cause
Corrective Action
1. Laser(s) appear
weak or are not
visible when
activated.
a. Software overload.
a. Cycle power.
b. Mode Selector is in O
(OFF) or P (PROGRAM)
position.
b. Turn Mode Selector to
desired position. Activate by
pressing the FIRE button.
c. Aim Neutral Density /
Opaque Lens Cap installed.
c. Uninstall the Aim Neutral
Density / Opaque Lens Cap
per Figure 2-15.
d. Laser port(s) obscured by
dirt, dust, or grime.
d. Clean laser port(s)
(section 3.2).