2-26
2.11 USING THE IR ILLUMINATOR (Continued)
IR Illuminator Pulse Rate
In addition to momentary and continuous modes of
operation, the IR Illuminator may be programmed to operate
in pulse mode at either 1, 2, 4, or 8 pulses per second.
NOTE
To access the programming mode, the Mode
Selector must be turned to the desired pulse rate
within 5 seconds of pressing the FIRE Button.
1. With the Mode Selector turned to the P (PROGRAM)
position, hold down the FIRE Button.
2. Turn the Mode Selector to the IR position that
corresponds to the desired pulse rate as shown in Table
2-9. The LED Status Indicator will display a flashing
green light that corresponds to the pulse rate (e.g., four
green flashes indicate a pulse rate of four pulses per
second).
Table 2-9. IR Illuminator Pulse Rates.
* The safety screw must be removed to program these pulse rates.
3. Release the FIRE Button, and the pulse rate will be
programmed. The set pulse rate will remain until it is
programmed differently.